C/10 NiCad & NiMH Chargers using
Regulated Charge Current,
Wall Plug-in and Desktop  Styles

General Purpose, Information Technology
and Medical Products

NiCad / NiMH C/10 Battery Chargers

  • Designed for use as an overnight charger. Approximately 14 hours required to recharge to full capacity.
  • User needs to manually remove the charger from the battery after full charge is reached.
  • Heavy Duty NiCad cells are available which can be charged at the C/5 rate.
  • NiMH cells may be damaged at the C/10 rate if left on continuously, contact the battery manufacturer for their recommendations. C/20 rate may be preferred in order to prevent battery performance loss due to inadvertent overcharge.

Standard Specifications 

  • Input Voltage: 120 Vac 60 Hz or 100,120, 230, 115/230 Vac 50/60 Hz
  • Operating Temperatures: 0 -40°C
  • Charge Current Tolerance: +/-10% @ Nominal Input Voltage
  • Designed for Continuous Duty
  • SELV Output
  • 3 Year Warranty

Available Features 

  • On-Off Power Switch
  • AC Power on LED
  • Charge Indicator LED
  • Dual Current Levels, Switch Selectable
  • Dual Current Levels, Timer Activated (F, K ,L & X case models)
  • Dual Current Levels, Voltage Level Dependent, (available on all models except B case)
  • Output Cord Sets and Connector Configurations
  • Case Colors, Markings and Company Logos

UL1310 / UL60950-1
Domestic Models

120 Vac, 60 Hz

Plug-In Case Size B H F K ---
DeskTop Case Size H F K X
IEC320 Case Size L K X
Power Code "1" "2" "3" "4" "5" "6"
Max Output Power Rating @ 12V 1.2W 2.4W 3.6W 6W 9W 18W
Model # Cells Nominal Battery Volts Charge Volts Charge Current / Amps Range
N[bcd]04-[gh] 4 4.8V 5.8V 0-.13 .13-.27 .27-.40 .40-.67 .67-1.0 1.0-2.0
N[bcd]05-[gh] 5 6.0V 7.25V 0-.13 .13-.25 .25-.37 .37-.62 .62-.93 .93-1.9
N[bcd]06-[gh] 6 7.2V 8.7V 0-.12 .12-.24 .24-.35 .35-.59 .59-.88 .88-1.8
N[bcd]07-[gh] 7 8.4V 10.2V 0-.11 .11-.21 .21-.32 .32-.53 .53-.79 .79-1.6
N[bcd]08-[gh] 8 9.6V 11.6V 0-.10 .10-.20 .20-.30 .30-.49 .49-.74 .74-1.5
Nbcd]10 -[gh] 10 12.0V 14.5V 0-.08 .08-.16 .16-.25 .25-.41 .41-.62 .62-1.2
N[bcd]12-[gh] 12 14.4V 17.4V 0-.07 .07-.14 .14-.21 .21-.35 .35-.53 .53-1.1
N[bcd]14-[gh] 14 16.8V 20.3V 0-.06 .06-.12 .12-.18 .18-.31 .31-.46 .46-.92
N[bcd]16-[gh] 16 19.2V 23.2V 0-.05 .05-.11 .11-.16 .16-.27 .27-.41 .41-.82
N[bcd]18-[gh] 18 21.6V 26.1V 0-.05 .05-.10 .10-.15 .15-.25 .25-.37 .37-.74
N[bcd]20-[gh] 20 24.0V 29.0V 0-.05 .05-.09 .09-.14 .14-.23 .23-.34 .34-.68

 

UL60601-1 Domestic Models &
EN60950-1 / EN60601-1
International Models

100, 120 or 230 Vac, 50/60 Hz
or
115/230 Vac 50/60 Hz

Plug-In Case Size H F --- ---
DeskTop Case Size H F K X
IEC320 Case Size L K X
Power Code "1" "2" "3" "4" "5" "6"
Max Output Power Rating @ 12V 1.2W 2.4W 3.6W 6W 9W 18W
Model # Cells Nominal Battery Volts Charge Volts Charge Current / Amps Range
N[bcd]04-[gh] 4 4.8V 5.8V 0-.13 .13-.27 .27-.40 .40-.67 .67-1.0 1.0-2.0
N[bcd]05-[gh] 5 6.0V 7.25V 0-.13 .13-.25 .25-.37 .37-.62 .62-.93 .93-1.9
N[bcd]06-[gh] 6 7.2V 8.7V 0-.12 .12-.24 .24-.35 .35-.59 .59-.88 .88-1.8
N[bcd]07-[gh] 7 8.4V 10.2V 0-.11 .11-.21 .21-.32 .32-.53 .53-.79 .79-1.6
N[bcd]08-[gh] 8 9.6V 11.6V 0-.10 .10-.20 .20-.30 .30-.49 .49-.74 .74-1.5
Nbcd]10 -[gh] 10 12.0V 14.5V 0-.08 .08-.16 .16-.25 .25-.41 .41-.62 .62-1.2
N[bcd]12-[gh] 12 14.4V 17.4V 0-.07 .07-.14 .14-.21 .21-.35 .35-.53 .53-1.1
N[bcd]14-[gh] 14 16.8V 20.3V 0-.06 .06-.12 .12-.18 .18-.31 .31-.46 .46-.92
N[bcd]16-[gh] 16 19.2V 23.2V 0-.05 .05-.11 .11-.16 .16-.27 .27-.41 .41-.82
N[bcd]18-[gh] 18 21.6V 26.1V 0-.05 .05-.10 .10-.15 .15-.25 .25-.37 .37-.74
N[bcd]20-[gh] 20 24.0V 29.0V 0-.05 .05-.09 .09-.14 .14-.23 .23-.34 .34-.68

Case Styles

Standard Input Cords

Standard Output Cords

 

Theory of Operation

Note:
Please specify, battery AHr capacity and charging current when ordering. If any additional series components such as diodes or resistors are used between the battery and the charger, then forward this information as well.

 

Safety Compliance 

     Designed to:
           UL 1310, 60601.1, 60950-1  
           CSA 22.2 #601.1, #60950-1, #223 
           EN 60601.1, 60950.1 & CE

   *P/N System abcdef-gh ex. (N P H N 10 - R1)

a - Nickel Chemistry Charger (N)
b - Mechanical (P=Wall Plug-In, D = Desktop, I = Desktop with IEC 320 Male Inlet)
c - Case Size (B, H, F ,L ,K , X)
d - Input Voltage/Frequency - (N = 120V 60Hz, M = 120V 50/60Hz, E: Euro = 230V 50Hz, U: UK = 230V 50Hz, A: Australian = 240V 50Hz, J: Japan = 100V 50Hz, S = 115/230V 50/60Hz)
ef - Battery Cell Count  ex. (10 = 10 cell battery)
g - Nickel Chemistry Charger Type - (R = C/10 Regulated Current, X = Timed Dual Current Level, Y = Voltage Level Dependent Dual Current Level)
h
- Power Code ex. ("H" Case Power Code 1 ) 

For more information or to place an order call (908) 353 5700,
or fax us at (908) 353 1021