General
Purpose, Information Technology
and Medical
|
 |
NiCad / NiMH C/10 Battery Chargers
- Designed for use as an overnight charger. Approximately 14 hours required to recharge to full capacity.
- User needs to manually remove the charger from the battery after full charge is reached.
- Heavy Duty NiCad cells are available which can be charged at the C/5 rate.
- NiMH cells may be damaged at the C/10 rate if left on continuously, contact the battery manufacturer for their
recommendations. C/20 rate may be preferred in order to prevent battery performance loss due to inadvertent overcharge.
Standard Specifications
- Input Voltage: 120 Vac 60 Hz or 100,120, 230, 115/230 Vac 50/60 Hz
- Operating Temperatures: 0 -40°C
- Charge Current Tolerance: +/-10% @ Charging Voltage
- Designed for Continuous Duty
- SELV Output
Available Features
- On-Off Power Switch
- AC Power on LED
- Charge Indicator LED
- Dual Current Levels, Switch Selectable
- Output Cord Sets and Connector Configurations
- Case Colors, Markings and Company Logos
Safety Compliance
Designed to:
UL 1310, 2601.1, 1950,
544
CSA 22.2 #601.1, #950,
#125, #223
EN 60601.1, 60950 &
CE
|
UL1310 /UL1950
Domestic Models |
120 Vac, 60 Hz |
| Wall Plug-In Only |
| Case Size |
E |
B |
H |
| Power Code |
"1" |
"2" |
"3" |
"4" |
| Max Output Power Rating |
1.6W |
3.2W |
4.8W |
6.4W |
| Model # |
Cells |
Nominal Battery Volts |
Charge Volts |
Charge Current / Amps Range |
| N[bcd]04-[gh] |
4 |
4.8V |
5.8V |
0 -.27 |
.27-.55 |
.55-.82 |
.82-1.10 |
| N[bcd]05-[gh] |
5 |
6.0V |
7.25V |
0 -.22 |
.22-.44 |
.44-.66 |
.66-.88 |
| N[bcd]06-[gh] |
6 |
7.2V |
8.7V |
0 -.18 |
.18-.36 |
.36-.54 |
.54-.72 |
| N[bcd]07-[gh] |
7 |
8.4V |
10.2V |
0 -.16 |
.16-.32 |
.32-.48 |
.48-.64 |
| N[bcd]08-[gh] |
8 |
9.6V |
11.6V |
0 -.14 |
.14-.28 |
.28-.42 |
.42-.56 |
| Nbcd]10 -[gh] |
10 |
12.0V |
14.5V |
0 -.11 |
.11-.22 |
.22-.33 |
.33-.44 |
| N[bcd]12-[gh] |
12 |
14.4V |
17.4V |
0 -.09 |
.09-.18 |
.18-.27 |
.27-.36 |
| N[bcd]14-[gh] |
14 |
16.8V |
20.3V |
0 -.08 |
.08-.16 |
.16-.32 |
.24-.32 |
| N[bcd]16-[gh] |
16 |
19.2V |
23.2V |
0 -.07 |
.07-.14 |
.14-.21 |
.21-.28 |
| N[bcd]18-[gh] |
18 |
21.6V |
26.1V |
0 -.06 |
.06-.12 |
.12-.18 |
.18-.24 |
| N[bcd]20 -[gh] |
20 |
24.0V |
29.0V |
0 -.05 |
.05-.11 |
.11-.16 |
.16-.22 |
UL2601-1 Domestic
Models and
EN60950 /EN60601-1
International Models |
100, 120 or 230 Vac 50/60 Hz
115/230 Vac 50/60 Hz |
Wall Plug-In, Desktop,
IEC320 Option |
| Case Size |
H |
| Power Code |
"1" |
"2" |
"3" |
"4" |
| Max Output Power Rating |
1.6W |
3.2W |
4.8W |
6.4W |
| Model # |
Cells |
Nominal Battery Volts |
Charge Volts |
Charge Current / Amps Range |
| N[bcd]04-[gh] |
4 |
4.8V |
5.8V |
0 -.27 |
.27-.55 |
.55-.82 |
.82-1.10 |
| N[bcd]05-[gh] |
5 |
6.0V |
7.25V |
0 -.22 |
.22-.44 |
.44-.66 |
.66-.88 |
| N[bcd]06-[gh] |
6 |
7.2V |
8.7V |
0 -.18 |
.18-.36 |
.36-.54 |
.54-.72 |
| N[bcd]07-[gh] |
7 |
8.4V |
10.2V |
0 -.16 |
.16-.32 |
.32-.48 |
.48-.64 |
| N[bcd]08-[gh] |
8 |
9.6V |
11.6V |
0 -.14 |
.14-.28 |
.28-.42 |
.42-.56 |
| N[bcd]10 -[gh] |
10 |
12.0V |
14.5V |
0 -.11 |
.11-.22 |
.22-.33 |
.33-.44 |
| N[bcd]12-[gh] |
12 |
14.4V |
17.4V |
0 -.09 |
.09-.18 |
.18-.27 |
.27-.36 |
| N[bcd]14-[gh] |
14 |
16.8V |
20.3V |
0 -.08 |
.08-.16 |
.16-.32 |
.24-.32 |
| N[bcd]16-[gh] |
16 |
19.2V |
23.2V |
0 -.07 |
.07-.14 |
.14-.21 |
.21-.28 |
| N[bcd]18-[gh] |
18 |
21.6V |
26.1V |
0 -.06 |
.06-.12 |
.12-.18 |
.18-.24 |
| N[bcd]20 -[gh] |
20 |
24.0V |
29.0V |
0 -.05 |
.05-.11 |
.11-.16 |
.16-.22 |
Note:
Please specify, battery AHr capacity and charging current when ordering. If any additional series components such
as diodes or resistors are used between the battery and the charger, then forward this information as well.
|