Gel Cell/Lead Acid Float Mode Battery Chargers

  • Provide optimum battery life in standby applications.
  • Will maintain fully charged battery at constant voltage. Used typically in the event of power failure or when charger is connected to battery during discharge.
  • Can be used as a power supply and charger combination

Automatic Dual Mode Battery Chargers

  • Will rapidly recharge batteries without danger of overcharge.
  • Should be used when batteries are repeatedly being discharged and recharged.

Standard Specifications

  • Input: 90-264 Vac 50/60 Hz
  • Operating Temperatures: 0-40°C
  • Output Voltage Tolerance: +/- 1%
  • Short Circuit & Overload Protection
  • Designed for Continuous Duty
  • Wall Plug-in or Desktop Configurations
  • All designs are approved or meet UL, CSA, TUV & CE requirements
  • 3 Year Warranty

Available Features

  • On-Off Power Switch
  • Temperature Compensated Charging Voltage
  • DC input for DC to DC Operation
  • LED's Indicating Power On and or High Charge
  • Output Cord Sets and Connector Configurations
  • Open Frame Construction (without enclosure)
  • Auxiliary Power Supply Output

Safety Compliance 

     Designed to:
               UL 60601-1, 60950-1  
               CSA 22.2 #601.1, #60950 
               EN 60601.1, 60950.1 & CE

ISO 9001 Registered

Float Mode

Enclosure/Power Code
(3rd and 4th model # digits)
"L1" "L2" "L3" "Z1" "Z2" "X2" "X3"
Enclosure Power Rating for
12V cell voltage
15W 21W 30W 48W 67W 96W 135W
Model # Cells Nominal
Battery
Volts
Float
Charge
Volts
Charge Current / Amps
WF**06* 3 6V 6.9V 2.2 2.8 3.6 6.0 8.4 12 15
WF**08* 4 8V 9.2V 1.6 2.2  3.0 4.8 6.7 9.6 13
WF**10* 5 10V 11.5V 1.3 1.8  2.4 4.0 6.4 8.0 11
WF**12* 6 12V 13.8V 1.1 1.5 2.2 3.5 5.0 7.0 9.8
WF**16* 8 16V 18.4V 0.81 1.2  1.6 2.6 3.6  5.2 7.3
WF**18* 9 18V 20.7V 0.72 1.0  1.4 2.3 3.2  4.6 6.5
WF**24* 12 24V 27.6V 0.55 0.75  1.1 1.75 2.5  3.5 5.0
WF**30* 15 30V 34.5V --- --- --- --- --- 2.8 3.9
WF**36* 18 36V 41.4V --- --- --- --- --- 2.4 3.3
WF**48* 24 48V 55.2V --- --- --- --- --- 1.75  2.5

Automatic Dual Mode

Enclosure/Power Code
(3rd and 4th model # digits)
"L1" "L2" "L3" "Z1" "Z2" "X2" "X3"
Enclosure Power Rating for
12V cell voltage
15W 21W 30W 48W 67W 96W 135W
Model # Cells Float
Charge
Volts
High
Charge
Volts
Charge Current / Amps
WD**06* 3 6.9V 7.35V 1.7 2.4 3.4 5.6 7.8 11 15
WD**08* 4 9.2V 9.8V 1.4 2.0 2.8 4.4 6.2 8.8 13
WD**10* 5 11.5V 12.25V 1.2 1.6 2.3 3.8 5.3 7.6 11
WD**12* 6 13.8V 14.7V 1.0 1.4 2.0 3.2 4.5 6.4 9.2
WD**16* 8 18.4V 19.6V 0.75 1.0 1.5 2.5 3.5 5.0 7.0
WD**18* 9 20.7V 22.05V 0.70 1.0 1.3 2.3 3.2 4.6 6.5
WD**24* 12 27.6V 29.4V 0.50 0.70 1.0 1.6 2.3 3.2 4.5
WD**30* 15 34.5V 36.75V --- --- --- --- --- 2.6 3.7
WD**36* 18 41.4V 44.1V --- --- --- --- --- 2.2 3.1
WD**48* 24 55.2V 59.2V --- --- --- --- --- 1.6 2.3


PART NUMBERING SYSTEM

1

2

3

4

5

6

7

Pos 1 & 2: From Model # in Tables

Pos 3 & 4: From Enclosure/Power Code at top of Tables

Pos 5 & 6: From Model # in Tables

Pos 7: An "M" in this position indicates a Medical model, additionally the following suffixes are used for L enclosure wall plug-in configurations (the Z and the X enclosure is not available as a wall plug-in.)

   "N": North American, Nema 5-15P
   "E": European, CEE7/16
   "U": United Kingdom, BS1363
   "A": Australian, AS3112

Example: WDL112M

Dual Mode, L1 Enclosure/Power Code, 12V Battery, Medical Use

   