- Universal Input Voltage:
90-264Vac 47-63Hz
- Output Voltage Regulation:
+/-2.5% Typical, +/-5% Max from Full Load to No Load.
- Operating Temperature:
0 - 40C
- Maximum Output Ripple:
5 - 6V: 50mVp-p
6.1 - 24V: 100mVp-p
24.1 - 36V: 150mVp-p
36.1 - 48V: 200mVp-p
- Designed for Continuous Duty
- Hold-Up Time : 25mS Minimum @ 120 Vin
- Short Circuit and Over Load Protection
- SELV Output
- MTBF Calculated > 100,000 Hours @ 40C
- 2 Hour Minimum Loaded Burn-in at 40C Ambient for standard output cord configurations
- Leakage current compliant to IEC60601-1 Category B and BF
- 3 Year Warranty
- See Lower Table for International Energy Efficiency Performance Key
Available Features
- Precision Output Voltage Setting
- Expanded Operating Temperatures
- Power On/Off Switch
- 400 Hz Input Rating
- DC Input Rating
- Additional Noise and/or Surge Protection
- LED Power On Indicator
- Output Cord
- Fixed-in-place Input Cord
- Wall Plug-in configuration
(for L Case only)
- Output Cord Sets and Connector Configurations
- Case Colors, Markings & Logos
- Output Voltage up to 100VDC
- 16 Hour Burn-in
- Output Leakage Current compliant to IEC60601-1 Category
CF
Regulatory Compliance
Designed for use with medical, information technology, and general purpose
equipment to the following standards:
All models are certified to:
UL 60601-1 / 60950-1
CSA 22.2 #601-1 / #60950-1 *
TUV EN 60601-1 / 60950-1
CE LVD directive
* cUL Mark
Resubmission required for 5V-11V models for alternate output current ratings
required for new Efficency Level 4 parameters (with the exception of the 7V, L
case model).
EMC
All models meet European EMC directive and FCC requirements.
Meet EMC all requirements from EN60601-1-2.
Emissions: Level B requirements of FCC CFR 47 part 15 and CISPR11 (EN55011) and
CISPR22 (EN55022), EN61000-6-3 (light industrial) and line harmonic emissions
EN61000-3-2.
Immunity: CISPR24 (EN55024), EN61326 and EN61000-3-2.
Certification records available upon project request.
|