Standard Specifications
- Universal Input Voltage:
90-264Vac 47-63Hz
- Output Voltage Regulation:
1% Typ., 5% Max., for a 100% to 0% Load change.
- Operating Temperature:
-20C to 50C, linearly derated to 70% of output power at 75C
- Maximum Output Ripple:
5.0 - 6.5V: 50mVp-p
7.0 - 16V: 100mVp-p
18 - 30V: 150mVp-p
32 - 48V: 200mVp-p
Note: 5-30V models: 150mVp-p
- Designed for Continuous Duty
- Hold-Up Time : 25mS Minimum @ 120 Vin
- Short Circuit and Over Load Protection
- High efficiency design meets Energy Star and Blue Angel operation guidelines.
No load power draw is less than 1 watt.
- SELV Output
- Low leakage input EMI filter meets 100uA medical leakage current category
for UL2601.1 type BF equipment
- EMI Immunity: Meets EN50082.1 requirements for ESD, modulated RF field and
EFT. Meets IEEE C62.41 Level A3 requirements
- EMC: Meets the EMC directive for Residential, Commercial and Light Industrial
- EMI Emissions: Meets FCC CFR part 15 class B, CISPR11, CISPR22, EN55011, EN55022
(All class B), Both Conducted and Radiated emissions 100% tested on all prototype
units. Radiated measurements by correlation procedure.
- Over 100,000 hours calculated MTBF at 40 C ambient temperature
- 2 Hour Minimum Loaded Burn-in at 40C Ambient
- 3 Year Warranty
Available Features
- Separate Battery Charger Output
- DC Input
- Additional Noise and/or Surge Protection
- Special Output Voltages
- Various Connector Configurations
- 16 Hour Burn-in
Dimensions
L Size = 3.0"W x 4.5"L x 1.6"H
L Diagram
Z Size = 3.5"W x 6.25"L x 1.9"H
Z Diagram
Regulatory Compliance
All models are certified to:
UL 60601-1 / 60950-1
CSA 22.2 #601-1 / #60950-1
TUV EN60601-1 / 60950-1
CE LVD/EMC directives
Products are UL certified to Canadian safety standards and marked with
the cUL mark. CE mark is based upon manufacturers self declaration.
Certification
records available upon project request.
|
Medical
and Information
Technology

|
|
"L" Size |
"Z" Size |
Model
Number |
Output
Voltage
Range |
Output
Current
Range |
Output
Wattage
Range |
Output
Current
Range |
Output
Wattage
Range |
| CS_791[a](M) |
5V to
6.5V |
8A to
6.2A |
40W |
12A to
9.2A |
60W |
| CS_792[a](M) |
7V to
9V |
5.7A to
4.4A |
40W |
8.6A to
6.7A |
65W |
| CS_793[a](M) |
10V to
16V |
4A to
3A |
48W |
6.7A to
5A |
80W |
| CS_794[a](M) |
18V to
30V |
2.7A to
1.6A |
48W |
4.4A to
2.7A |
80W |
| CS_795[a](M) |
32V to
48V |
1.5A to
1.0A |
48W |
2.5A to
1.7A |
80W |
| CS_796[a](M) |
5V to
30V |
3A to
1.5A |
15-45W |
5A to
2.5A |
25-75W |
| CS_895[a](M) |
5V to
30V |
3A to
1.5A |
15-45W |
5A to
2.5A |
25-75W |
| +12V Aux. |
150mA |
800mA |
| Specify "L" or "Z" Size in Model Number underscore |
| (M) option on part number indicates medical compliant safety design
and markings. |
| Specify "A" for *Adjustable
output or "P" for **Programmable
output in Model Number [a] |
| *Adjustable output voltage
feature uses a single turn potentiometer accessible from the bottom surface. |
| **Programmable output voltage
feature requires an analog DC voltage source from 0.5 to 4.5Vdc to define the
output voltage. Additional information
on this feature: |
|
ISO 9001 Registered |