Lithium Ion, Lithium Polymer Chargers
Switchmode Technology
Medical and Information Technology
- Input: 90-264 Vac 50/60 Hz
- Operating Temperatures: 0-40°C
- Output Voltage Tolerance: +/- 1%
- Short Circuit & Overload Protection
- Designed for Continuous Duty
- Wall Plug-in or Desktop Configurations
- All designs designed to meet UL, CSA, TUV & CE requirements
- 5 Year Warranty
Standard Specifications
- On-Off Power Switch
- LED's Indicating Power On and High Charge
- Output Cord Sets and Connector Configurations
- Case Colors, Markings and Company Logos
- Open Frame Construction (without enclosure)
- Step back to 3.9V/Cell Float Voltage after completion of Full Charge Cycle
Available Features
Safety Compliance
    Designed to:
              UL 60601-1, 60950-1 Â
              CSA 22.2 #601.1, #60950-1Â
              EN 60601.1, 60950.1 & CE
| Enclosure/Power Code(3rd and 4th model # digits) | "L1" | "L2" | "L3" | "L4" | "Z1" | "Z2" | "Z3" | |||
| Enclosure Power Rating for 12.6V charge voltage | 10W | 20W | 30W | 50W | 75W | 100W | 120W | |||
| Model # | Cells | 4.1 V/ Cell Charge Volts | 4.2V / Cell Charge Volts | Charge Current / Amps | ||||||
| WJ**01* | 1 | 4.1V | 4.2V | 2.2 | 2.8 | 3.6 | 6 | 8.4 | 12 | 15 |
| WJ**02* | 2 | 8.2V | 8.4V | 1.6 | 2.2 | 3 | 4.8 | 6.7 | 9.6 | 13 |
| WJ**03* | 3 | 12.3V | 12.6V | 1.3 | 1.8 | 2.4 | 4 | 6.4 | 8 | 11 |
| WJ**04* | 4 | 16.4V | 16.8V | 1.1 | 1.5 | 2.2 | 3.5 | 5 | 7 | 9.8 |
| WJ**05* | 5 | 20.5V | 21.0V | 0.81 | 1.2 | 1.6 | 2.6 | 3.6 | 5.2 | 7.3 |
| WJ**06* | 6 | 24.6V | 25.2V | 0.72 | 1.0 | 1.4 | 2.3 | 3.2 | 4.6 | 6.5 |
| WJ**07* | 7 | 28.7V | 29.4V | 0.55 | 0.75 | 1.1 | 1.75 | 2.5 | 3.5 | 5 |
| WJ**08* | 8 | 32.8V | 33.6V | --- | --- | --- | 1.4 | 2.0- | 2.8 | 3.9 |
PART NUMBERING SYSTEM
Pos 1 & 2: From Model # in Tables
Pos 3 & 4: From Enclosure/Power Code at top of Tables Pos 5 & 6: From Model # in Tables Pos 7: An "M" in this position indicates a Medical model, additionally the following suffixes are used for L enclosure wall plug-in configurations (the Z enclosure is not available as a wall plug-in.) Â Â Â "N": North American, Nema 5-15P
   "E": European, CEE7/16
   "U": United Kingdom, BS1363
   "A": Australian, AS3112 Example: WJL102M Lithium Charger , L1 Enclosure/Power Code, 2 cell battery, Medical Use
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
Pos 3 & 4: From Enclosure/Power Code at top of Tables Pos 5 & 6: From Model # in Tables Pos 7: An "M" in this position indicates a Medical model, additionally the following suffixes are used for L enclosure wall plug-in configurations (the Z enclosure is not available as a wall plug-in.) Â Â Â "N": North American, Nema 5-15P
   "E": European, CEE7/16
   "U": United Kingdom, BS1363
   "A": Australian, AS3112 Example: WJL102M Lithium Charger , L1 Enclosure/Power Code, 2 cell battery, Medical Use